Suitable for 15-60W mains irons only!

  ............S T A N D....................           ....I R O N.........

   Fuse ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
 L o-oÄÄ(ÄÄÄÄÂÄÄÄÄÄÄ¿           +³  10uF       3 core    Boost     ³
   1A   ³   _³_    _³_          === 350V       cable     Press  SOLDERING
        ³   \_/    /_\           ÀÄÄÄÄÄÄÄ22RÄÄÄÄÄÄÄÄÄÄÄÄ> \       IRON
        ³    ³      ³                    1W                ³     ELEMENT
        ÀÄÄÄÄ´      ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÙ
             ³          Economize o    ³       or 4 core
       4x    ³      ÚÄÄÄÄÄÄÄÄÄÄÄÄÄo <ÄÄÙ       with earth
      1N4006_³_    _³_     Normal  Gravity
            /_\    \_/             Switch
 N ÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÙ
 E -------------------------------------------------------------------

When on the stand the mains fed to the iron is half wave only for economiser
mode (1/2 power), the iron rest on a suitably mounted stand micro switch that
is connected to one of the bridge diodes. When the iron is picked up, full wave
is restored for (normal power).

An added non locking press button switch mounted in the iron handle, this
boosts the power by connecting a 350V 10uF with a 22R in series (47uF/10R for
60W) housed in the stand (iron not earthed 3 core cable! Or use 4 core rubber
flex with an earth) resulting in approx 300V peak DC from the mains being used
for high power. This is approx 2x the normal power, hence the non locking press
switch!

Make sure all mains connections & switches are safe (properly shrouded heat-
shrink) to avoid shocks etc.

A neon (with series 220k) across iron can be used to indicate the power status.

     _._+340V             _._                 _._    _._        _..__ _..__
    /   \                /   \               /   \  /   \      /     '     '
0V.³.....³.......³   0V.³.....³______³   0V.³.....³³.....³   0V............... 
  ³       ³     ³
    NORMAL \_ _/          ECONOMY            FULL POWER         BOOST POWER
    MAINS    ' -340       « POWER              RAW DC           SMOOTHED DC


Also see my Tech Bul on "Thermostatic Soldering Iron LED".


Why Don't U send an interesting bul?
 