|
G8MNY > TECH 05.04.17 10:28l 71 Lines 3028 Bytes #999 (0) @ WW
BID : 39726_GB7CIP
Read: GUEST
Subj: PTT line for Drake L-4B PA
Path: IZ3LSV<I0OJJ<GB7CIP
Sent: 170405/0903Z @:GB7CIP.#32.GBR.EURO #:39726 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To : TECH@WW
By G8MNY (Updated Jul 07)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ÚÄÄÄÄÄÄÄ¿
³ÚÄÄÄ¿ _ _ ³³ ³
³ÀÄÄÄÙ (_) (_) ³³ ³
³ÚÄÄÄ¿ _ ³³ ³
³ÀÄÄÄÙ (_) ø ø³³ ³
³ o [|]³³ ³
ÀÄÂÂÄÄÄÄÄÄÄÄÄÄÄÂÂÄÙÀÂÂÄÄÄÂÂÙ
THE PROBLEM
If wired directly to a IC735 Tx send connector, the IC735 reed relay contacts
weld up with the linear relay's back emf.
L I N E A R I C 7 3 5
18V AC S4 _____ SEND PTT
())))ÄÄ´>ÃÄÄÂÄÄÄÂÄ/oÄÄÄ´relayÃÄÄÄÄÂÄÄ´>ÃÄÄo o)ÄÄ> \ Tx reed
===== === ³ ~~~~~ ³ PTT ³ ³ relay
³ ³ ³ ³ ³ contact
100u³ 2k2 10n=== GND ³ ³
0VÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄo ÀÄÄÄÄÁÄÄÄ
This old large valve HF PA uses an inductive 12V PTT relay that is runs on
unregulated 18V.
MY CURE
Originally not wanting to modify either pieces of kit, I chose to find a simple
fool proof solution in the inter connecting lead.
To stop the back emf & in-rush current to the IC735's reed relay SEND contact,
I added a 35V 4u7 in series with a 100ê across linear's PTT 2 pin plug to
terminate the back emf.
L I N E A R I C 7 3 5
18V S4 _____ P L U G SEND PTT
())))ÄÄ´>ÃÄÄÂÄÄÄÂÄ/oÄÄÄ´relayÃÄÄÄÄÂÄÄ´>ÃÄÄo ÄÄÄÂÄÄÄÄÄÄ(o o)ÄÄ \ Tx reed
===== === ³ ~~~~~ ³ PTT 100ê ³ ³ ³ relay
³ ³ ³ ³+ ³ ³ ³ contact
100u³ 2k2 10n=== GND === 4u7 ³ ³ ³
0VÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄo ÄÄÄÁÄÄÄÄÄÄÙ ÀÄÄÄÄÁÄÄÄ
L E A D
The added operate & release delay is not detectable (a few 1mS?), & there is no
longer shocking back emf to feel or weld up the rig contact, if U manually
earth the phono plug etc.
But later I overhalled the PA & modified the PTT relay with the usual diode
across it, this may slow the change to Rx a few milliseconds, but stops all
relay back emf.
L I N E A R I C 7 3 5
18V S4 _____ P L U G SEND PTT
())))ÄÄ´>ÃÄÄÂÄÄÄÂÄ/oÄÂÄ´relayÃÄÂÄÄÂÄÄ´>ÃÄÄo ÄÄÄÄÄÄÄÄÄÄ(o o)ÄÄ \ Tx reed
===== === ³ ³ ~~~~~ ³ ³ PTT ³ ³ ³ relay
³ ³ ÀÄÄÄ´<ÃÄÄÄÙ ³ ³ ³ ³ contact
100u³ 2k2 1N4001 10n=== GND ³ ³ ³
0VÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄo ÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÁÄÄÄ
See my Tech buls on "ALC line for Drake L-4B PA", "Using 2 HF PAs", "Power
Factor of Drake L-4B PA" & "Valve Heater delay Drake L-4B PA".
Why Don't U send an interesting bul?
73 de John, G8MNY @ GB7CIP
Read previous mail | Read next mail
| |