G8MNY > TECH 16.01.17 11:31l 63 Lines 2810 Bytes #999 (0) @ WW
BID : 31735_GB7CIP
Read: GUEST
Subj: Rotator Alinco info
Path: IZ3LSV<F1OYP<ON0AR<GB7CIP
Sent: 170116/1004Z @:GB7CIP.#32.GBR.EURO #:31735 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To : TECH@WW
By G8MNY (updated Nov 05)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
This is basic & reliable rotator with manual switch controls & regulated meter
heading readout.
___________ ___ /ºº\ Stub Mast
³ ÚÄÄÄÄÄÄÄ¿ ³ \ ³ ºº ³ Clamp Castings
³ ³ .-"-. ³ ³ \ _³_ºº_³_
³ ³'_____`³ ³ ³ / \
³ 0 ³ ³ 6 Wire ³__________³ ROTATOR
³ --------- ³ ³ Cable ³________³
³ ³o³ [I] ³ _.Ù ³ ºº ³ À option flat
³___________³_.-' Support ³ ºº ³ base plate
CONTROLLER Mast Clamp \ºº/ remove clamp
DIAGRAM
LÄoÄÄoÄ¿ ÚÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 6 *ÄÄÄÄÄÄÄ¿
Fuse )º( ³ ³ AC Common ³
240V )º( ³ 33ê left 2x 8ê ³
)º( 24V ³ ³ ÚÄo\ oÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄ* 5 *Ä())))Ä´
)º( ³ ³ ³ ===130uF AC ===== ³
NÄo/'oÄÙ ÃÄÄÄÄ)ÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÄÁÄo/ oÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄ* 4 *Ä())))ÄÙ
ON ³ ³ _³_ Right MOTOR
³ 120ê \_/
³ ³ ÃÄÄÄÂÄÄÄÄÄ¿
³ ³ ³ 470ê ³/' 8.5V
³ ³ ³ ÃÄÄÄ´ REGULATOR
³ ³ ³ ³ ³\e
³ ³ ³ ³ ÀÄ100êÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 2 *ÄÄÄÄ¿
³ LAMP +³ ³ ³ _ ³
³ ³ === ÃÄÄÄ¿ 10n=== /~ ~\ CAL ROTOR
³ ³ 470u³ _³_ `\³ ,, ÃÄÄ´MeterÃÄÄÄ8kÄÄ* 3 *ÄÄÄ>POT
³ ³ ³ '/_\ ÃÄÄÄÄÄÄ´ - \._./ + PRESET 500R
³ ³ ³ 9V³ e/³ ''FB ³ ³
³ ³ ³ ³ ³ 27ê ³
ÀÄÄÄÄÁÄÄÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 1 *ÄÄÄÄÙ
CURRENT LIMITER
* = External Connection
N.B. *1* to *6* = 24V AC could be useful for things!
The circuit could have been wired to use only 5 wires if the switch feed & AC
common were reversed, making 1 the new AC common to the motor, as well as the
pot earth.
MODS
1/ As with most rotators the motor is well over run, so if high usage (eg more
than 2 mins) is needed then add a high wattage low value R (eg 8ê 10W) in
series with the motor common (*5*). This will increase motor run time before
it overheats, without significantly reducing the available torque.
2/ Also a 0u5 Cap across the mains will correct the transformer's power factor
for /P operation (but not the motor run PF!).
Why Don't U send an interesting Bul?
73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail
| |