This is quite a complex circuit design with 2 relays & uniquely it is only a 3
wire system for proper comparison pot type controller.

                                             (=º\  Stub Mast
                                               º ³ Clamp Castings
        _.---------------.                 __(=º_³_
    _.-'.- ' " `;_   _.-' |               /        \
 .-'   \__ . -'/_/.-'      |    3 Wire   (__________) ROTATOR
ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿-"       _.:|   Cable     ³________³
³              ³  _..-:'-'"                  ³ º=)  À option flat
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁ:'-"'                Support ³ º       base plate
     CONTROLLER                    Mast Clamp \º=)     unbolt clamp

DIAGRAM
          ÚÄÄÄÄÄoÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄ* 2
  RUN    º( red 2   MOTOR &                                         ³
rÚo/ o¿r º(         FLOATING                                        ³
 ³ __ ³w º(  27V    BRIDGE                                          ³
NÁo  oÁÄ¿º( red 1   SUPPLY                                          ³
 START  )ºÀÄÄÄÄÄoÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄ)ÄÄÄÄ¿
        )º                +ÚÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÂÄÄÄÄÄ¿    R3         R2    ³
240V    )ºÚÄÄÄÄoÄÄÄÄÂÄÄÄ¿  ³ R2         ³   R5     ³    10k        1k    ³
        )º( bl 3    ³   ³  ³ 1k         ³   2M2    ³   ³/           ³    ³
   1A r )º(        _³_ _³_ ³  o         ³    ÃÄÄÄÄÄ)ÄÄÄ´           _³_   ³
LÄÄoÄoÄÄÙº(12-0-12V/_\ \_/ ³  ³rd       ³   _³_    ³   ³\e         /_\D9 ³
  Fuse   º(__o4    -³D4 ³+ ³ _³_LED     ³   \_/D2  ³    _³_D1       ³    ³
         º(  ³Ye ÚÄÄ´ -7ÃÄÄ´ \_/        ³   _³_D3  ³    \_/     VR1 ³    ³
         º(  ³   ³ _³_ _³_ ³  ³bn     Q3³   \_/   7³  2  ³   ÚÄÄ3k3Ä´    ³
         º(  ³ 5 ³ \_/ /_\ ³  o       NPN\³__³ 6 ,/'ÃÄÄÄÄ´ CONTROL _³_ZD1³
          ÀÄÄ)ÄoÄ)ÄÄÁÄÄÄÙ  ³  ³  _____  e/³  ÃÄÄ<741³ 3  ³   POT   \_/,  ³
         bl  ³   ³         ³  ÃÄ´ RUN ÃÄ´    ³   `\.ÃÄÂÄÄ)Ä>10k    ~³~   ³
             ³   ³         ³  ³ ³RELAY³ e\³__ÃÄ´ÃÄÄ)ÄÄ´  ³   ÀÄÄ3k3Ä´    ³
             ³   ³         ³  ³ ÀÄÄÄÄÄÙ  /³   3n3  ³4 ³  ³      VR2_³_D8 ³
             ³   ³  -      ³  ³      PNP³ Q4       ³  ³  ³         /_\   ³
             ³   ÃÄÄÄÄÄÄÄÄÄ)ÄÄ)ÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÙ  ³+ ³          ³    ³
             ³  ===C2   C3=== ³                   C4 === ³        R1 1k  ³
             ³  +³10u   10u³- ³                   4u7 ³  ³          ÀÄÄÄÄÁ* 1
             ÀÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 3
                               SU-2000A PCB
               o = PCB Connection           * = External Connection

ROTATOR DIAGRAM
 2 *ÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄ¿
     1k    _______³_______   ³+   ³
    _³_   ³DIRECTION RELAY³ ===   ³
    /_\   ÀÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÙ  ³10u ³
     ³            ÃÄÄÄÄÄÄÄÄÄÄÙ    ³
     ³           _³_              ³
     ³           \_/              ³
     ÃÄÄÄÄ¿       ³               ³
    _³_  ROT    ³/      AC  ÚÄÄÄÄÄÁÄÄ¿
    \_/, POT<ÄÂÄ´     MOTOR )||    ||(
    ~³~  10k  ³ ³\e   2x 8ê )||    ||(
     ÃÄÄÄÄÙ   ³  _³_        )||    ||(
    _³_       ³  \_/        )||    ||(
    /_\       ³   ³         ³        ³
     ³        ³   ³    ÚÄÄÄÄ´ 50V AC ³
    1k        ³   ³    o   === 68uF  ³
 1 *ÄÁÄÄÄÄÄÄÄÄ)ÄÄÄÁÄ./'o____³________³
 3 *ÄÄÄÄÄÄÄÄÄÄÙ     Relay

OPERATION
After rotating the HEADING pot to the desired direction & pressing the START
button the LED is lit from the +ve rail & the RUN relay operates holding the
mains on, as the bridge will be off balance & either + or - from the opamp will
via Q2 or Q3 will hold the RUN relay on until a balance is reached.

When the op amp output is high Q1 is turned on putting some DC unbalance on the
motor feed. This is sensed during the bridge unpowered half cycle in the motor
head unit & turns on the transistor to operate the DIRECTION relay. The
DIRECTION relay determines the AC phase & hence direction of rotation of the 2
pole AC motor.

Preset pots VR1 & VR2 set the end scale length for the control pot to match the
rotator pot.

FAULTS
I have experienced the 4 white blob type diodes in the rotator head unit
falling apart with corrosion, despite the rest of the circuit being in clean
condition.