|
G8MNY > TECH 20.04.16 08:45l 70 Lines 3521 Bytes #999 (0) @ WW
BID : 1926_GB7CIP
Read: GUEST
Subj: Rotator Western WE1145 info
Path: IZ3LSV<IW0QNL<JH4XSY<JM1YTR<JE7YGF<N9PMO<ZS0MEE<CX2SA<GB7CIP
Sent: 160420/0727Z @:GB7CIP.#32.GBR.EURO #:1926 [Caterham Surrey GBR] $:1926_GB
From: G8MNY@GB7CIP.#32.GBR.EURO
To : TECH@WW
By G8MNY (Updated Nov 05)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
º\
º ³ Clamp Castings
. ---------------. ___=º_³_
_.-'.- ' " `;_ _.-' | / \
.-' \__ . -'/_/.-' | 5 Wire (__________) ROTATOR
ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿-" _.:| Cable ³________³
³ ³ _..-:'-'" ³ º= À option flat
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁ:'-"' Support ³ º base plate
CONTROLLER Mast Clamp \º= remove clamp
This is quite a complex circuit design with 2 relays etc.
DIAGRAM
ÚÄÄÄÄoÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 5 *ÄÄÄÄÄÄÄ¿
RUN º( red 5 MOTOR & C1 === ³
rÚo/'o¿r º( FLOATING 4u7 +ÃÄÄÄ¿ 2x 8ê ³
³ __ ³ wº( 27V BRIDGE _³_ ³ ÚÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄ* 4 *Ä())))Ä´
NÁo oÁÄ¿º( red 4 SUPPLY D1 /_\ ³ CW2 o ===68uF ===== ³
START )ºÀÄÄÄÄoÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄ)ÄÄo/'oÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄ* 3 *Ä())))Ä´
)º 3 ³ 8 3k MOTOR ³
240V )ºÚÄoÄÄÄÄÄÄÄÄÄÂÄÄÄ¿ R2 ÚÄÄoÄÄÄVR1ÄÄÄÄÄÄ* 2 *Ä¿ ³
1A r )º( bl _³_ _³_ 1k2 HEADING /³\ ROTATOR<ÄÙ
LÄÄoÄoÄÄÙº(12-0-12V /_\ \_/ CONTROL ÀÄÄoÄÄ>POT 10k ³ 3k POT 10k
Fuse º(__o2 -³ ³+ SUPPLY 9 ÀÄÄoÄÄÄÄ)ÄÄVR2ÄÄ* 1 *ÄÙ
º( ³Ye ÚÄÄ´ ÃÄÄÂÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄ¿ 10 ³ /³\
º( ³ ³ _³_ _³_ ³ R2 ÚÄÄÄÄÁÄÄÄ¿ ³ ³ ³ RESISTANCE
º( ³ 1 ³ \_/ /_\ ³ 1k2³ ³CW RELAY³ R3 ³ ³ BRIDGE
EÄÄÂÄÄÄÄÄÙÀÄÄ)ÄÄoÄÄ)ÄÄÁÄÄÄÙ ³ o ÀÄÄÄÄÂÄÄÄÙ 10k ³ ³
_³_ ³ bl ³ D2-5 ³ <-_³_ ÚÄÄ´ X2 ³ ³ ³
//// ÚÄÄÄÄÄÁÄÄÄ¿ ³ ³ <-\_/ ³ \³ ³ ³ ³
³RUN RELAY³ ³ ³ LED³ ³ ÃÄÄÄÄ´ ³ ³
ÀÄÄÄÄÄÂÄÄÄÙ ³ CW1 o o _³_ e/³Q2 \³Q1 ³ ³
X1 ÀÄÄÄÄÄ)ÄÄÄÄÄÄo/'o ³ /_\ ³ ÃÄÄÄÄ´ ³
³ ³ ³ D7³ ³ e/³ _³_ ³
³ ³ ³ ³ ³ ³ D6/_\ ³
ÀÄÄÄÄÄÄÄÄÄÁÄÄÄÄÁÄÄÄÄÁÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÙ FU200 PCB
X=No of Contacts o = PCB Connection * = External Connection
OPERATION
After rotating the HEADING pot to the desired direction & pressing the START
button the LED is lit. Then the CW RELAY (Clockwise) either operates or stays
released, this determines the AC phase direction selected for the motor. In
either case the RUN relay is powered until the balance point of the 2 pot
resistance bridge is reached when Q1, Q2, & the CW relay change state. The RUN
relay is then fast released with reverse power & the mains supply is
disconnected & the LED extinguishes.
Preset pots VR1 & VR2 set the scale length for both the HEADING & ROTATOR pots,
& should be set so that the rotator always stops before the mechanical end stop
is reached at either end of the HEADING pot.
MODS
As with other rotators the motor is well over run, so if you want more than 2
mins run time add a high wattage low value R (e.g. 8ê 10W) in series with the
CW2 switch common, this will increase motor run time before it overheats or
burns out!
Why Don't U send an interesting Bul?
73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail
| |