G8MNY  > TECH     20.08.08 07:59l 78 Lines 3516 Bytes #999 (0) @ WW
BID : 317_GB7CIP
Read: GUEST
Subj: NISSAN Generator GL600 info
Path: IZ3LSV<IK2XDE<ON4HU<F5GOV<CX2SA<YV6BTF<ED1ZAC<GB7CIP
Sent: 080819/2240Z @:GB7CIP.#32.GBR.EU #:317 [Caterham] $:317_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

By G8MNY                                       (New Mar 06)
(8 Bit ASCII graphics use code page 437 or 850)
I repaired one of these small old 4 stroke petrol generators with no
information. Although it has the same features & looks much the same as the
HONDA EX500 however it is tiny bit larger & more powerful.

      .ÄÄÄÄÄÄÄÄÄÄÄ.                  ÚÄ¿Breather      .ÄÄÄÄÄÄÄÄÄÄÄ.
     / /~~~~~~~~~\ \              _  ³ ³Handle       / /~~~~~~~~~\ \   Spark
 ,ÄÄÁÄÁÄÄÄÄÄÄÄßßßÄÁÄÁÄÄ,       ÚÄÁÄÁÄÁÄÁÄÄÄÄÄ¿   ,ÄÄÁÄÁÄÄÄÄÄÄÄÄÄÄÄÁÄÁÄÄ.Plug
 Ý\__________Fuel Tank³Þ   Run ³[]__  o ÚÄÄÄ¿³   Ý              ÚÄÄ/~\ Þ
 Ý_Choke cable\______/ Þ  Start³ /||\ o ³_"_³³   Ý              ³ ³~~~³Þ  Carb
Þ  ~~~~~~----------Tap  Ý & Off³ \||/o oÀÄÄÄÙ³  Þ            RPM³ ÀÄÄÄÙ ÝÄDrain
Þ        F        Pull  Ý      ³  ~~ DC   AC ³  Þ            arm³ ÚÄÄÄ¿ Ý_RPM
³ Crank  A      StartÚ¿ ³      ³             ³  ³   ___Exhaust  ³ ³AIR³ ³ ADJ
³ Case   N ALTERNATOR³³ ³      ³             ³  ³  ³ o ³        ³ ³FIL³ ³
³                    ÀÙ ³      ³             ³  ³  ÀÄÄÄÙ   Gov o³ ÀÄÄÄÙ ³Oil
ÀÂÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÂÙEarth ÀÂÄÂÄÄÄÄÄÄÄÂÄÂÙ  ÀÂÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÂÙ
  ~                   ~          ~  Feet   ~      ~                   ~

The NISSAN GL600 was seized SOLID after being used in the wet (flood) & then
stored for a few months!

It would not turn over on the pull start. So I put "WD40" in the spark plug
hole & stripped down the pull starter, to get a much better purchase on the
engine. Using a long leaver & a U clamp on the pull start catch points of the
flywheel, I was able to free up the engine. After that is all worked OK. The
watery oil was changed.

Conclusion, do not to store a drenched generator, without turning it over
occasionally.


CIRCUIT
I have reverse engineered the diagram!

   OFF      gn
  Úo\ÄÄÄÄÄÄÄÄ==ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
  ÃÄÄÄÄÄÄÄÄÄÄÄ*ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÂÄ0 EARTH    ³     Normal
  E         bk                  _³_  rd/wh _³_           ³     Magneto
 AC         bn             ALT                 CASE      ³     Ignition
N   LÄÄo-oÄÄÄÄ*ÄÄÄÄÄÄÄÄÄÄÄ¿                              ÃÄÄÂÄÄ¿    ÚÄÄÄ¿
³    3A Trip         240V )||    ÚÄÄ´>ÃÄÄ¿              \³/ ³   )||(   \³/Spark
³           wh        20ê )|| S  ³_())))_³       Contact / ===  )||(   /|\Plug
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄ*ÄÄÄÂÄÄÄÄÄÄÄ)|| T    =====        Breakers ³  ³1u )||(    ³
                  ³  18V  )|| A    ROTOR        (points) ³  ³   )||(    ³
0v          ye    ³  1.5ê )|| T                          ÃÄÄÁÄÄÁÄÄÄÄÁÄÄÄÙ
>ÂÂÄÄÄÄÄÄÄÄÄÄÄ*ÄÄÄ)ÄÄÄÄÄÄÄ)|| O                         _³_
 ³³  75ê          ³    6V )|| R   EXCITOR             ENGINE
 ³ÀÄFREQÄ==ÄÄÄ*ÄÄÄ)ÄÄÄÄÄÄÄ)||      =====
RUN  IND    bl    ³   18V )||     _(((()_
LAMP            wh*  1.5ê ³gn    ³       ³
18V               ³       ³      ³       ³
 ÀÄÄÄÄÄÄ¿        _³_     _³_     ÀÄÄ´ÃÄÄÄÙ
+12V    ³   rd   \_/     \_/         C
>ÄÄÄo-oÄÁÄÄÄÄÄ*ÄÄÄÁÄÄÄÄÄÄÄÙ
  10A Trip    Diodes on Heatsink

== Bullet Connector
 * Connector

Note that the DC is connected to the 230V! So the 230V will no longer be safely
floating if it is used with the DC! Also the DC is 20V off load!

No voltage regulation modification was needed as this generator is very good.

See my bul on "Regulating 12V genny output" for the circuit that I use with it.

Also see my bul called "Petrol Generators for /P SSB" for solving this
generators ignition QRM.


Y Don't U send an interesting bul?

73 de John G8MNY @ GB7CIP