OpenBCM V1.08-5-g2f4a (Linux)

Packet Radio Mailbox

IZ3LSV

[San Dona' di P. JN]

 Login: GUEST





  
G8MNY  > TECH     19.12.13 09:27l 87 Lines 4330 Bytes #999 (0) @ WW
BID : 48674_GB7CIP
Read: GUEST
Subj: Eagle DB120 Sound Meter
Path: IZ3LSV<I0OJJ<GB7CIP
Sent: 131219/0715Z @:GB7CIP.#32.GBR.EU #:48674 [Caterham Surrey GBR] $:48674_GB
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

By G8MNY                                        (New Dec 07)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)

The is a simple cheap sound meter.
     ____                                        PCB LAYOUT
ÚÄÄÄÁÄÄÄÄÁÄÄÄ¿                                ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³³~~~~~~~~~~³³                                ³    /~~~\    ³
³³ \        ³³                                ³Q12³METER³VR2³
³³  \       ³³                                ³    \___/    ³
³³__________³³ 40dBA-120dBA in 2 ranges       ³             ³
³        ____³ In built calibrator            ³VR1      __  ³
³       /~~\ ³                                ³Ú¿ Q5  /~  ~\³
³      ³    ³³                                ³³³    ³SWITCH³
³       \__/ ³                                ³³³IC   \_  _/³
³        ~~~~³                                ³ÀÙ   VR3 ~~  ³
³            ³                                ³             ³
³ EAGLE      ³                                À¿   ÚÄÄÄ¿   ÚÙ
³            ³                                 ³VR5³   ³VR4³
³            ³                                 ÀÄÄÄÙ   ÀÄÄÄÙ
ÀÄÄÄÄÄÄÄÄÄÄÄÄÙ

CIRCUIT
 ÚÄÄÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÄ2k2ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÂÄ<+ve
 ³    56k  ³   ³                      ³          ³    OPAMP
 ³  +  ³ ³/    ³+                     ³          ³    The TD7120 provides
MicÄ´ÃÄÅÄ´Q3  ===                     ³         56k   fixed stable gain
 ³ 4u7 ³ ³\e   ³33u                  7³ ÚÄÄÄ¿    ³    to drive the non the
 ³    56k  ³   ³      Low           2³~\³3 56k   ³    linear metering stage.
 ³     ³  VR3ÃÄ)ÄÂÄÄÄÄÄÄÄo<Ä2k2ÄÄÂÄÄÄ´TA\  6³    ³ +
 ³     ³  Mic  ³14k4           150k  ³7120>ÄÁÄÄÄÄ)ÄÄ´ÃÄÄ3k3Ä>
 ³     ³  cal  ³ ÃÄÄÄÄÄÄÄo       ÃÄÄÄ´  /ÀÄÂÄ19kÄ´+ 10u
 ³     ³   ³   ³220  High       +³  5³_/ 1 ³    ===
 ³     ³   ³   ³ ³           10u===   ³4  ===3n3 ³10u
 ÀÄÄÄÄÄÁÄÄÄÁÄÄÄÁÂÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÁÄÄÄÄÁÄÄÄÄÄÁÄ<
                ÀÄÄVR1ÄÄÂo Cal
                   200  ³    ÚÄÄÄÄÂÄÄÄÂÄÄÄÄÂÄÄ5k1ÄÄ<+ve
                       220k  ³   33k 33k   ³
PREAMPS                 ³   3k9   ³   ³   3k9
The 3 wire electret mic ÀÄÄÄÄÅÄÄ´ÃÁ\ /Á´ÃÄÄ´
& preamp Q3 is powered        \³    X    ³/
from a decoupled rail.       Q2ÃÄÄÄÙ ÀÄÄÄ´Q1
                             e/³ ASTABLE ³\e
VR2 calibrates the mic       ÀÄÄÄÄÄÄÂÄÄÄÄÄÄÙ
capsule & VR1 calibrates           100
the astable calibrate             ÄÄÁÄÄÄ<
oscillator Q1&2.

METER DRIVER                                                oOff
+ve<ÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄ¿e  ÚÄÄÂÄÄÂÄo<ÄÄÄÂÄÄ¿
                10k ³/                    47u³+  \ /  2k2 ÃÄoHigh³  ³
                 ÃÄÄ´Q5                     === ÄÄÂÄÄ  ³  ÀÄoCal ³  ³
                _³_ ³\e         +10u         ³  Q7ÃÄÄÄÄÙ  ÚÄoBat ³  ³
                \_/   ÃÄÄÄÄ560ÄÄÂÄ´ÃÄÄÂÄÄÄ¿  ³    ³       ³  oOff³  ³
                _³_   ÃÄÄ¿     +³     ³   ³  ³    ³       ³      ³  ³
     D1         \_/ ³/e  ³     ===10u ³   ³  ³   _³_      ³      ³  ³
  ÚÄ´>ÃÄ¿        ÃÄÄ´Q6 100k    ³     ³   ³  ³   /_\'     ³     === ³+
  ³     ³      ³/   ³\   ³    ÚÄÁÄ¿   ³   ³  ³    ³       ³      ³ BATT
>ÄÅÄ2k2ÄÅÄÄÂÄÄÄ´Q4    ³  ³   _³_ _³_ _³_ _³_ ³    ³       ³      ³ PP3
  ³     ³ 100k ³\e    ³  ³   \_/ /_\ \_/ /_\ ³    ³       ÃÄÄÄ¿  ³  ³
  ÀÄ´<ÃÄ´  ÀÄÄÄÄÄ)ÄÄÄÄ)ÄÄ´+   ³D9 ³D8 ³D7 ³D6³    ³      VR3 680 ³  ³
     D2 ³       220   ³ ===   ³   ³   ³   ³  ³    ³      50k  ³  ³  ³
        ³        ³    ³  ³10u ³   ³   ³   ³  ³    ³       ³   ³  ³  ³
<ÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÂÄÁÄÄÄÄÁÂÄÁÄÄÄÄ)ÄÄÄÁÄÄÄÁÄÄÄ)ÄÄÁÄÄÄÄÁÄÄÄÄÄÄÄ)ÄÄÄÁÄÄÁÄÄÙ
        ³  10u===     ===10u  ³           ³               ³
      D3ÃÄ´<ÃÄÄÁÄÄVR5ÄÄÁÄÄÄÄÄÄÁÄÄÄ´>ÃÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄ´
        ³          5k             D10     ³ VR4 33u===  Meter
      D4ÀÄ´>ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄ2kÄÄÄÄÄÁÄÄÄÄÄÙ

To get a usable 40dB scale on a meter quite a lot of compression is needed.
This circuit uses an AGC approach. Transistors Q4, 5 & 6 from a power amp to
drive the double voltage doubler bridge D6-10 rectified load of the meter &
also provide AGC with D3 & D4 making an variable input attenuator.

VR5 set the AGC log action & diodes D1 & D2 correct for over compression to get
the very linear 40dB scale. VR4 is the main calibrate & VR3 is the battery cal.


See my bul on "Sound Levels dBA dBB dBC".


Why don't U send an interesting bul?

73 de John G8MNY @ GB7CIP


Read previous mail | Read next mail


 06.11.2024 04:00:16lGo back Go up