OpenBCM V1.08-5-g2f4a (Linux)

Packet Radio Mailbox

IZ3LSV

[San Dona' di P. JN]

 Login: GUEST





  
G8MNY  > TECH     10.06.12 23:58l 64 Lines 2353 Bytes #999 (0) @ WW
BID : 45747_GB7CIP
Read: GUEST
Subj: 70-260V Mains Auto Transformer
Path: IZ3LSV<IK2XDE<DB0RES<ON0AR<GB7CIP
Sent: 120610/2203Z @:GB7CIP.#32.GBR.EU #:45747 [Caterham Surrey GBR] $:45747_GB
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

By G8MNY                                (New Jul 11)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
This is a poor variac substitute, but made with a suitable transformer & large
wafer switch, it can provide useful mains test voltages.

Voltages shown are for simplicity of calculation only!

CIRCUIT
                  ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄo 260V
 Fuse 1  On       ³     ÚÄÄÄÄÄÄÄÄÄÄ)ÄÂÄÄÄo 240V
L Äo-oÄÄÄo\oÄÂÄÄÄÄ)ÄÄÄÄÄ)ÄÄÄÄÄÄÄÂÄÄ)Ä)ÄÄÄo 220V <ÄÄÄÄ L
(220V)       ³.   ³     ³   -   ³  ³ ÃÄÄÄo 200V
              )||.ÃÄÄÄÄÄ)ÄÄÄo <ÄÙ  ³ ³ ÚÄo 180V
         110V )||( 40V  ³      220 ÀÄ)Ä)Äo 150V
        ______)||(______³      110   ÃÄ)Äo 120V
       ³______.||( 20V  ³   + <ÄÂÄÄÄÄ)Ä)Äo 110V
       ³      )||( 0V  LAMP o   ³    ÀÄ)Äo  90V
       ³ 110V )|| ÀÄÄÄÄÄÁÄÄÄÁÄÄÄ)ÄÄÄÄÄÄÁÄo  70V
       ³   ___)||               ³
       ÀÄÄ(ÄÄÄÄÄÄÄÄÄÄÄÄo-oÄÄÄÄÄÄÙ
          ³           Fuse 2
N ÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ N

E ÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ E
   _³_
     
Here the 110/220V switching & phase reverse switching (+ or -) of the 40V
secondary is not shown. If a good multi wafer switch is not available, then a
plug board may be more suitable.

SAFETY
To stop switch arcing or shocks on a plug board, only change voltage with the
mains OFF! The inclusion of a 20V lamp (not accessible!) is useful to remind
you!

All housing & wiring etc. should be up to mains standards & also let heat out.

The power rating of the transformer will set the max current at a voltage...

 VOLTS     MAX LOAD CURRENT       e.g. 80W Transformer
  260     Full Secondary                  2A
  240     1.5 x Secondary                 3A
  220       Infinite                    Fuse Limit
  200     1.5 x Secondary                 3A
  180     Full Secondary                  2A
  150     2x Transformer rating         0.6A (220/80 x2)
  130     2x Transformer rating         0.6A
  110     2x Transformer rating         0.6A
   90     2x Transformer rating         0.6A
   70     2x Transformer rating         0.6A

So for an 80W transformer Fuse 1 can be 2 or 3A, & Fuse 2 a 1A.

See also my tech bul on "Maplin Mains Meter 2000MU-UK","Mains Power Protection"
& "Saveplug Motor Economiser".


Why don't U send an interesting bul?

73 De John, G8MNY @ GB7CIP


Read previous mail | Read next mail


 08.11.2024 19:11:41lGo back Go up