G8MNY > TECH 20.10.11 06:46l 76 Lines 2820 Bytes #999 (0) @ WW
BID : KALFC1MAC002
Read: GUEST
Subj: Coax Faulting
Path: IZ3LSV<IK6ZDE<F1OYP<FC1MAC
Sent: 111020/0531z @:FC1MAC.FAQI.FRA.EU [Saint priest] OBcm1.07b5
From: G8MNY @ FC1MAC.FAQI.FRA.EU (Daniel)
To: TECH @ WW
X-Info: Sent with login password
R:111020/0530Z @:F1MAC.FAQI.FRA.EU #:29090 [St priest] FBB7.00i $:15348_GB7CIP
R:111019/2250Z @:F1OYP.FAQI.FRA.EU #:201 [Saint-Astier] FBB7.00e $:15348_GB7CIP
R:111019/2049z @:IK6ZDE.IMAR.ITA.EU $:15348_GB7CIP
R:111019/2152z @:IZ3LSV.IVEN.ITA.EU $:15348_GB7CIP
R:111019/2050z @:IK2XDE.ILOM.ITA.EU $:15348_GB7CIP
R:111019/2150z @:DB0RES.#NRW.DEU.EU $:15348_GB7CIP
R:111019/2050z @:ON0AR.#AN.BEL.EU $:15348_GB7CIP
R:111019/2140Z @:GB7CIP.#32.GBR.EU #:15348 [Caterham] $:15348_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To : TECH@WW
By G8MNY (New Aug 10)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
Here is a simple practical method of finding a short on a long run of coax. It
assumes a temporary test wire can be run from end to end & that the coax inner
& outer are continuous, resistive damage in the outer or a corroded short
(as wired below) will not affect the measurements.
CONNECTIONS
Faulty shorted coax
Car __________________________________
ÚÄÄLampÄÂÄ()_________________________________)ÄÂÄÄÄ¿
12V ³ / \ ³ ³
Floating V1 V2 ³
³__________________________________________________³
Test wire
Here it is assumed the inner is OK & it has constant resistance per length. (if
this is not true see "DAMAGED INNER" below)
The 12V supply must be floating so it can be reversed & have no currents to
earth.
The lamp wattage sets a suitable current down the inner conductor so that at
least a few 100mV will be across it. (this may need 5A for thick LDF cables
etc.)
CIRCUIT
Faulty shorted coax
Car
ÚÄÄLampÄÂÄÄÄÄÄÄÄÄÄR1ÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄR2ÄÄÄÄÄÂÄÄÄ¿
³ ³ Corrosion_Ü_battery ³ ³
³ ³ ____________________³_____________ ³ ³
12V ³ / No current in outer \ ³ ³
Floating V1 V2 ³
³__________________________________________________³
Test wire
With a sensitive DMV measure V1 & V2, then reverse the 12V polarity & repeat.
Average the readings at each end (ignore polarity) to cancel any corrosion
voltage at the short.
Now the total inner conductor voltage drop is just V1+V2
V1
And the fault position is ÄÄÄÄÄ x Length, from the lamp end.
V1+V2
DAMAGED INNER
If the inner is damaged more than the outer (water corrosion) then make the
outer the current carrier.
See TECH buls on "Cable Tester", "Coax Feeder Tests" & "A Versatile Pulse
Tester".
Why don't U send an interesting bul?
73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail
| |