G8MNY > TECH 15.04.11 08:01l 101 Lines 4116 Bytes #999 (0) @ WW
BID : 12703_GB7CIP
Read: GUEST
Subj: Marconi Distortion Meter TF2331
Path: IZ3LSV<ED1ZAC<GB7CIP
Sent: 110415/0005Z @:GB7CIP.#32.GBR.EU #:12703 [Caterham] $:12703_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To : TECH@WW
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
I have on one of these old AF distortion meters. It uses a variable Wien Bridge
to make a deep 80dB notch for removing the signal tone.
Level Freq Band Cal Distortion Meter
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ .Ä~~~Ä. n () /~~~~\ ()³Power
³ ( ) / \ ( ) / .' \ ³
³ ³ ( ) ³ u \ú / ³
³ n \ / ~Ä--Ä~ ³
³ ( ) 'Ä___Ä' n n ³
³ u o ( ) ( ) ³Range
³ | ( ) ( ) u u ³
³ O O ß O O ³Output
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
In Balances Function LF CUT
Level Ranges:- 30V, 10V, 3V, 1V, 300mV, 100mV, 30mV, 10mV, 3mV, 1mV.
:- 30, 20, 10, 0, -10, -20, -30, -40, -50, -60dBm
Responce :- 20Hz - 100kHz @ -2%, 50Hz-55kHz -1%
Distortion Frequency:- 20Hz - 20kHz in 6 bands.
Distortion Ranges: 30%, 10%, 3%, 1% min to 0.2%
& dBs -10 -20 -40 -40 min to -55dB
The distortion measurement needs the zero level reference level to be set. Then
the Waine bridge notch is finely adjusted to null out the fundamental, so just
the harmonics are left. As LF hum can also be filtered out with an LF reject if
needed. The
In ÚÄÄÄÄÄ¿ ÚÄÄÄÄÄ¿ ACÚÄÄÄÄÄ¿ ÚÄÄÄÄÄÄÄÄÄÄÄ¿
oÄÄ´LevelÃÄ´InputÃÄÂÄÄÄÄ´LevelÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´LEVEL METERÃÄÄÄÄÄ¿
³Atten³ ³ Amp ³ ³ ³Det 1³ DC ÀÄÄÄÄÄÄÄÄÄÄÄÙ ³
ÀÄÄÄÄÄÙ ÀÄÄÄÄÄÙ ³ ³ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³
³ ÀÄÄÄÄÄÙ ÚÄÄÄÄÁÄÁÄÄÄÄÄ¿
³ ÚÄÄÄÄÄÄÄÄÄ¿ ³ DISTORTION ³
³ oÄ´400Hz HPFÃÄo ÚÄÄÄÄÄ¿ ÚÄÄÄÄÄ¿ ³2 COIL METER³
³ ÃÄÄÄÄÄÄÄÄÄ´ ³ Set ³ ³Level³ ÀÄÄÄÄÂÄÂÄÄÄÄÄÙ
À>oÄ´ 1kHz HPFÃÄo<Ä´Gain ÃÄÄ´Det 2ÃÄÄÄÄÄÄÄÙ ³
ÀÄÄÄÄÄÄÄÄÄÙ ³ Amp ³ ³ ÃÄÄÄÄÄÄÄÄÄÙ
oÄ External ÄÄo ÀÂÂÂÂÂÙ ÀÄÄÄÄÄÙ DC
^ÄÄÙDist Range
It just uses simple RC transistor Amps & bridge diodes for the electronics. The
notches are sealed LC high Q units. (M derived?)
There are only 3 presets:- Level gain, Distortion gain, & input amp Bias.
DISTORTION MEASURING PRINCIPLES
f1 f2
³ f1 0dBÄ´ | ÚÁÄÄÄÄÄÄ ³ f1
Level³ ³ f2 ³ | ³ High ³ f2
³ ³ ³ f3 ³ | ³ Pass ³ ³ f3
³ ³ ³ ³ f4 f5 -60dB_³___|_/ Filter ³ ³ ³ f4 f5
ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÀÄÄÄÄÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁ
Distorted Signal Filter Filtered Signal
The high pass filter must completely remove the fundamental & ale LF hums etc.
but leave all the harmonics intact. The detectors (especially the distortion
one) should be a true RMS type, as the waveform will generally be very complex
& nothing like a sine wave. The ratio of f1 to all the harmonics f2+++ is the
distortion factor.
Calibration is done by adding in a 2nd tone (e.g. 3-10x freq) via high value Rs
at say 10% of the level to indicate 10% distortion. The distortion meter
bandwidth can also be checked with this circuit.
1V 1kHz Äo-oÄÄÄ10kÄÄÂÄÄÄÂÄÄÄÄÄÄ¿
Osc 1 o ³ ³ ³
_³_ ³ ³ Distortion
³ DVM Meter
100mV ³ _³_ _³_
2-20kHz Äo-oÄÄÄ10kÄÄÙ
Osc 2 o
_³_
To check the HPF filter is working OK a very pure sine wave is needed, so an LC
tuned circuit after a sig gen is used. But I did find that > 0.5V @ resonance
on the meter did make the inductor distortion rise > 0.01% !
Osc 88mH 500mV
50mV 1kHz ÄÄÄ((((()ÄÄÂÄÄÄÄÄ¿ Hi Z
low Z ³ Distortion
³ 0.28uF === Meter
_³________________³_____³
See my bul "Simple 1kHz AF osc".
Why don't U send an interesting bul?
73 de John, G8MNY @ GB7CIP
Read previous mail | Read next mail
| |