          Model 99-5076

ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³³~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~³³ DC Volts  0.25 2.5 10 50 250 1000  @ 25K/V
³³                               ³³           0.125 1.25 5 25 125 500  @ 50K/V
³³ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿³³
³³³³~~~~~~~~~~~~~~~~~~~~~~~~~~~³³³³ DC Amps   50uA 5mA 50mA 500mA 10A  @ Normal
³³³³                           ³³³³           25uA 2,5mA 25mA 240mA 5A @ 2x
³Æµ³ .                         ³Æµ³
ÀÙ³³  '.                       ³³ÀÙ AC Volts  3  10  50  250  1000     @ 2.5K/V
Ú¿³³    '.       .             ³³Ú¿           1.5 5  25  125  500      @ 5K/V
³³³³      '.   :'\':           ³³³³
³Æµ³        '. 'ú.ú'           ³Æµ³           10x dB scales & DC isolated AC.
³³³ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ³³³
ÀÙ³ÄÄÄÄÄÄÄÄÄ¿         ÚÄÄÄÄÄÄÄÄijÀÙ Ohms «FSD 13R 65R 650R 6K5 65K
  ³  o-  +o ³   (|)   ³ o    o  ³
  ³         ³         ³         ³   Accurancy DC 2%, AC 3%
  ³ [± ]rev ³_________³  «[ ±]  ³
  ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

MULTI METER PRINCIPLES

DC VOLTS                         1000  100   10   1 Volts
To get a meter of just one         Ú10MÄÂÄ1MÄÂ100KÂÄÄÄ11K1ÄÄÄÄ>+
sensitivity to do many             o    o    o    o
ranges voltage multiplier             /³\
resistors are used. Here              +³
the voltage drop across              /~~~\
the meter is ignored, but           ³Meter³
it will affect the lowest        90uA\___/
1V scale.                              ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>-
Series resistors are used
to protect the switch more            Sensitivity is 11K1/V
from high voltages.

DC CURRENT                                100uA 1mA 10mA 100mA
For current ranges shunts             +ÚÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>+
are put across the meter.            /~~~\    \³/
Here the meter resistance           ³Meter³ o    o    o    o
is 100R so it has 10mV drop     100uA\___/       ³    ³    ³
@ 100uA. The 1mA shunt here      10mV  ³        11R  1R   0R1
is corrected for the 100R              ÀÄÄÄÄÄÄÄÄÄÁÄÄÄÄÁÄÄÄÄÁÄÄ>-
meter load.

AC VOLTS
For AC a rectifier diode is
used, & normally this alters          1000  100   10 Volts
the sensitivity, so a different         Ú4M5ÂÄ450KÂÄÄÄÄ45KÄÄÄÄ>~
multiplier arm the DC is used.          o    o    o
In this circuit only half the                  /³\
current goes through the meter        +ÚÄÄÄ´<ÃÄÄ´
& the 1.1 AC sine wave form          /~~~\  D1 _³_D2
factor means that 2.2x meter        ³Meter³    /_\
current must flow. Only a       100uA\___/      ³100uA
100mV is lost in the germanium         ÀÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄ>~
diode D1, so the low voltage
range can take this into account
on the scale. D2 can be any type         Sensitivity is 4K5/V.
& protects the low voltage D1.

OHMS
Here a voltage source is put
in series with the meter & a
known resistance that set the
half scale resistance & includes                      (actually -ve!)
the meter load resistance.             ÚÄÄCal Zero RÄÄÂÄÄÄÄÄÄÄ>+
The higher the battery                +³             \³/
voltage the higher resistance        /~~~\      o   o  o   o
that can be measured, but           ³Meter³  Ú10Á100Á1KÁ10KÙ
becomes a danger for            100uA\___/   ³
sensitive electronics.                 ³     ³     ³+
The Cal zero R sets the meter          ÀÄÄÄÄÄÁÄÄÄÄÛÃÄÄÄÄÄÄÄÄÄÄ>-
sensitive to give full scale                       ³  (actually +ve!)
ZERO reading on shorting the
probes depending the battery state.

Note that the battery internal resistance is added to the unknown resistance,
& this affects the low range scale calibration! Also the probe polarity is
reversed to that indicated & it is different than for digital meters!

ACTUAL MULTIMETER CIRCUIT
ÚÄ===========================================================================
³                              I
³Ú========================= =============== ================  ===========   =¿
\/                                     ÀÄ20KÄÄ80KÄ¿     ³     ³              ³
/\                                       /³\      ³     ³     ³Com  + 10A O/P³
³ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿                    ³       ³     ³     ³  o  o  o  o  ³
³    ____  ÚÄ¿       ³ ÚÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÁÄÄÂÄÄ)ÄÄÄÄÄ)ÄÄ´  ³u1³  ³  ³
³   /15uA\ ³ ICal    ³ ³   13             ³   Low    ³ 13K  ÚÄ)ÄÄ)ÄÄÁ´Ã)ÄÄÙ  ³
³ Ú´ Meterô ÃÄÄÄÄÄÄÄ)Ä)Ä¿  ³            46K Ú4K7´<ô  ³   ³ ³  ³     ³     ³
³ ³ \____/ ³12K5     ³ ³ ³  ³             ³  oNor³  3K3 ³   ³ ³  À0R025´     ³
³ ³        ³ ³       o o ³  ³             ³Ú>    ³   ³  ³   ³ ³        ³     ³
³ ÃÄÄ´>ÃÄÄÄ´ ÀoNor Ú> X <Ù  ³             ³³ o«  ³  5kHi³   ³ ³        ³     ³
³ ÃÄ´<ÃÄÄÄÄ´   <ÄÄÄ´ o o    ³             ³³ À4K7Á´>ÃÁÄÄÙ   ³ ³      0R475   ³
³ ÃÄÄVCalÄÄÙ ÚoVA/2³Rev Nor ³             ³³  Low           ³ ³        ³     ³
³ ÀÄÄÄÄÄÄÄÄÄÄÁÄ6K25Ù       Ú)ÄÄÄÄÄÄÄÄÄÄÄÄÄ))ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´ ÀÄÄÄÄÄÄÄÄ)¿    ³
³                          ³³             ³³                ³ ÚÄÄÄÄÄÄÄÄÙ³    ³
ÀÄÂ56K25Â197K5Â1MÂ5MÂ18M75¿³Ã47Â650Â6K54¿Ú´³Ú1M87ÂM5ÂM1Â17K5´ Ã4R53Â45R3Å24K9´
  o     o     o  o  o     o³o  o   o    o³o³o    o  o  o   o´ o    o    o    o
                           ³   I         ³ ³                ³
  =========================Ù=============Ù À================ÃÄ================
                               I                            ³
                            ===============¿____³Ü³Ü________³
                                               +³ß³ß
0.25   2.5   10 50 250   1k R/5 R 10 100 1k 1k  250 50 10  3 500  50    5  50u
\________DC_VOLTS_________/ \_____OHMS____/ \___AC_VOLTS___/  \____DC_mA____/
                                               & dB Scales

The configuration switching between modes & all the ranges is all done on just
1 large rotary switch with 3 bridging contacts (I) & 5 wipers of 2 circuits.

Only 4 probe sockets are used, 2 extra for the high current (10A) & the DC
isolated AC measurement.

Extra switches provide a meter reverse feature & a double sensitivity that
doubles the number of meter ranges. (has no meaning on ohms!)

This meter's movement is a extremely sensitive @ 15uA for FSD, but not very
accurate, so it is calibrated with an ICal & VCal presets at manufacture.

The AC ranges are calibrated with select on test resistors 2x "4K7 Low" & the
"5K Hi" that accurately allows for the diode forward resistance loss & leakage.

Most of the resistors are special values made for the meter, & of course they
are very accurate & stable 0.5% types.


See my tech buls on "Meter Movement Types", "Maplin Mains Meter 2000MU-UK",