G8MNY  > TECH     22.03.09 09:49l 80 Lines 4028 Bytes #999 (0) @ WW
BID : 21151_GB7CIP
Read: GUEST
Subj: BURNS's MF-UHF Wavemeter TC-101
Path: IZ3LSV<IK2XDE<DB0RES<ON0AR<GB7CIP
Sent: 090321/2342Z @:GB7CIP.#32.GBR.EU #:21151 [Caterham] $:21151_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

By G8MNY                                                (New Mar 09)
(8 Bit ASCII Graphics use code page 437 or 850)
Here is a reverse engineered diagram & layout of one I picked up the other day.

It covers 800kHz through to 500MHz in 6 bands with a very accurate set of 6
180ø easy to read scales.

LAYOUT
ÚÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³³                                          ³³        PROBE
³³                                          ³³          _ 2 turn
³³                                          ³³         ( )Search
³³                       1n                 ³³          ± Coil
³³                      o Ý                 ³³          ±
³³    L6    L5       D1 ____________        ³³          ±
³³  =(-)= =(-)=       À(___³  20pF  ³       ³³          ±Insulated
³³    ~     ~ E   L4    L1 ³ Tuning ³       ³³          ±handle
³³        L3    =(-)=      ÃÄÄÄÄÄÄÄÄ´   1n  ³³          ±
³³       =(-)=           n_³  Cap   ³    Ý  ³³          ±
³³  -   +           SW  /  ³ 100pF  ³ D2 o  ³³          ±
³³ÚÄÁÄÄÄÁÄ¿   pot  ===== L2ÃÄÄÄÂÂÄÄÄÙ   22k ³³          º
³³³ Meter ³  ÚÁÁÁ¿ =====__/    ³³Vernier ´~~³³          º
³³³       ³  ³___³ ÄÂÁÂÄ      ====       ´  ³³          ºCoax
ÀÅÁÄÄÄÄÄÄÄÁÂÄÄÅÄÅÄÄÄÅÄÅÄÄÄÄÄÄÄÄÅÅÄÄÄÄÄÄÂÄÅ==ÁÙ          º
  ~~~~~~~~~   ±±±   ±±±   ~~~~±±±±~~~~ ÃÄ´ Phones       º
              Sens   SW       Tune   InÀÒÙ              º
                                        ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ

CIRCUIT
                      SW oÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                         oÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿      ³
Phones        D2   L2a   oÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿      ³      ³
 ==>ÄÄÄÄÂ22k´<ÃÂÄÄ(()ÄÄ>oÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿      ³      ³      ³
  _³_   ³   ³   ³_       oÄÄÄÄÄÄÄÄ¿     ³      ³      ³      ³
        ³1n===  ³/|      o        ³     ³      ³      ³      ³ ÚÄo SW
        ³  _³_ === ÚÄÄÄÄÄÙ        ³     ³      ³      ³ ÚÄÄÄÄ)Ä)Äo
        ³     /_³_ ³              ³     ³      ³ ÚÄÄÄÄ)Ä)ÄÄÄÄ)Ä)Äo
        ³     100pF³              ³     ³ ÚÄÄÄÄ)Ä)ÄÄÄÄ)Ä)ÄÄÄÄ)Ä)Äo<ÄÄ(o Probe
        ³          ³     D1       ³ ÚÄÄÄ)Ä)ÄÄÄÄ)Ä)ÄÄÄÄ)Ä)ÄÄÄÄ)Ä)Äo  _³_ Input
       Sens        ÃÄÄÄÄ´<ÃÄÄÄ¿ ÚÄ)Ä)ÄÄÄ)Ä)ÄÄÄÄ)Ä)ÄÄÄÄ)Ä)ÄÄÄÄ)Ä)Äo
       10k         ³   _ÚÄÄÄ¿ ³ ³ ³ ³   ³ ³\   ³ ³\   ³ ³\   ³ ³\
50uA   Log        === ³\³ L1) ³ ³ ) ³ L3)|³/\  )|³/\  )|³/\  )|³/\
MeterÄ>Pot       1n³   ===  )ÄÙ ³ )ÄÙ   )|(  L4)|(  L5)|(    )|(L6
880R    ³          ³20pF³\  )Ä)ÄÙ )L2b  )|(    )|(    )|(    )|(
 ³     82R         ÃÄÄÄÄÁÄÄÄÁÄÙ   ³    /ÃÄÙ   /ÃÄÙ   /ÃÄÙ   /ÃÄÙ
 ÃÄÄÄÄÄÄÙ         _³_Strip Loop  _³_   _³_    _³_    _³_    _³_Earths
_³_
                      500-200  200-57  57-18  18-6   6-2.2  2.2-0.8MHz

HOW IT WORKS
The input from a 2 turn loop probe feeds low impedance test signals to the
input. The 6 pole 2 bank switch is actually a 4 bank band change type with 2
earthing contacts banks on the unselected bands. The lower 4 bands the ferrite
cored preset coils L3-L6 are quiet conventional with a 1 turn drive primary,
the layout not too important.
                                                                    _
The tuning capacitor is a constant frequency snail shaped type,   /~ ~\
with offset shaft. A constant C/angle would be no good really!   ÀÄOÄÄÄÙ
                                                               
For the VHF range L2 is a thick wire loop split into two by the switch. Layout
is everything to getting the right L & stay capacitance for the indicated
frequency on this range.

On the same tuning cap there is a UHF 20pF section & a 2cm long copper strip
folded across it that forms L1. The coax drive tap is placed 25% from ground, &
the diode D1 detector on the 50% top of the U bend. Again layout & small size
at UHF is needed for stable calibrated scale.

Note that in this circuit the geranium/Schottky diodes D1 & D2 are in series on
UHF range! But this does not affect the sensitivity much with the 50uA meter.



Why Don't U send an interesting bul?

73 de John G8MNY @ GB7CIP


Read previous mail | Read next mail