G8MNY > TECH 19.03.09 08:20l 121 Lines 5852 Bytes #999 (0) @ WW
BID : 20890_GB7CIP
Read: GUEST
Subj: Driving Inductive Loads
Path: IZ3LSV<IK2XDE<DB0RES<ON0AR<GB7CIP
Sent: 090318/2253Z @:GB7CIP.#32.GBR.EU #:20890 [Caterham] $:20890_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To : TECH@WW
By G8MNY (New Jan 09)
(8 Bit ASCII Graphics use code page 437 or 850)
If you have ever tried to get a tape recorder head current flat, magnetic
cutting pickup, LF scope scan coils, hearing aid loop etc, you will be aware is
not very efficient & impossible to match over a wide frequency range.
TYPICAL HEAD LOAD
Z ê RMS Volts
100k´ .ú'Ã100
30k´ .ú' Ã 30
10k´ .ú' Ã 10
===== 3k´ .ú' Ã 3
(((() 1k´ .ú' Ã 1
³ ³ 300´ .ú' Ã .3
100´___.ú' Ã .1
ÅÄÄÄÄÂÄÄÄÄÂÄÄÄÄÂÄÄÄÄÂÄÄÄÄÂÄ>Frequency
0 10 100 1k 10k 100k Hz
Theory says the impedance Z starts as the DC resistance & then the coil
inductance takes over as you increase frequency. As the impedance gets higher
at higher frequency the self & lead capacitance will resonate coil making the Z
go very high.
So trying to design a driving stage to give constant magnetic field (or force)
is really impossible. What is normally done in the Valve era was to use a high
series resistor from a high power stage, so the constant current was fed in as
the head Z was always much lower than the series R.
HT
³ Bias Osc
)||( PLayback LS Input>ÄÄ´\ ====
)||( Winding ³ñ>ÄÄÄÂÄ´ÃÄ((()ÄÄ¿
)|| ÚÄÄ< HF Bias ÚÄÄÄ´/ ³ Record
ÃÄÄÄÄ´ÃÄÄÄ100kÄÄÄ´ ÃÄÄÄÂÄÄRfbÙ Head
/~³~\ 0.2u )||Record R ===C ³
³ ÄÁÄ ³ )||Head ÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁ
³ ³ )|| R & C give 6dB/O lift
³
Old Valve Circuit Typical Semiconductor Circuit
For tape record a large HF bias voltage is applied too. For transistorised
equipment especially battery powered using such a wasteful approach is not
used. Instead pre-emphisis is used to predict the head current & drive the head
from a lower impedance. This gives a flat response OK, but it has the problem
that higher drive voltage than is available is needed for LOUD treble, so most
simple designs just cause treble clipping (SHUSHY treble) & this is often
mistaken for poor tape etc.
ONE SOLUTION
Many years ago I made a tape recorder from scratch using an old Valve type tape
deck & I knew there would be this problem with a semiconductor design. I came
up with this approach still using the AF amp as a drive source, but a step up
transformer that gradually came in at HF to boost the voltage available at the
treble end to give the full unclipped recording level.
ÚÄÄÄÄÄÄ10kÄÄÂÄ<HF Bias
)||48mH ³
³\ 1000u )|| RECORD
³ >ÄÄ´ÃÄÄÄÄ)||1:10 HEAD
³/ )|| _³_
Ú
=== C
_³_
At bass to mid the constant current came from the series 10k, from mid to treble
the step up came in as the cap C & the tapping ratio were chosen to give the
drive required step up to maintain the full head current for tape saturation.
MAGNETIC DEFLECTED X/Y SCOPE
I have a 12" one of these, I use for displaying a spectrum analyser adaptor.
It uses constant current power output drivers with current NFB. The whole thing
runs terribly hot, as any display offset (e.g. trace at the bottom of screen)
needs huge standing current from a low voltage supply, & at only a few 10s of
kHz the supply is far to low to give much deflection.
_
³ +10V
+10V @8A Drive ³._
Display Amp ³ ³ _³ ³ _ DISPLAY
_ Input Ä´\³ ³' ³' ____
ÀÄÙ ÀÄÙ ³ñ >ÄÄÄÂÄÄÄ¿ ³ ³_10v Þ Ý
ÚÄ´/³ 220 1ê)|| Y Yoke Ý Þ
³ ³ ³ )|| Coil Ý Þ Ý Þ
ÀÄÄÄ)ÄÄÄÄÁÄÄÄ´ Þ____Ý Þ____Ý
³ 0.1R Slopping sides on large
-10V @8A _³_ verticals due to lack of volts
Putting the yoke coil in the NFB loop gives the required voltage to frequency
uplift of 6dB/Octave, but due to the coil there is a time delay that causes
instability, so the amp gain has to be reduced at HF to make this circuit work.
Unlike with audio, the signal phase is important on scopes. so no bodges really
work well. :-(
DEAF AID LOOP
Here is another inductance load! The main problem here is not to overload to a
driving amp etc. & still give plenty of treble.
TV ÚÄÄÄÄÄÄÄÄÄ¿ Equivalent Loop Circuit
³\LS ³ ³
³ >ÄÄÄÂÄÄRsÄÂÄÙ LARGE ³ L
³/³ ³ ³ ROOM ³ ___()))))_______R cable____
³ ÀÄÄ´ÃÄÙ LOOP ³ ³ ³
³ Cs ³ ÀR radiationÙ
³_____________________³ (very little)
(at audio)
Rs makes up the total DC resistance to not less than 8 ohms, & it has to handle
most of the LS amp power (1-5W). Cs (e.g. 1-10uF) can then boost some of the
treble if needed, as the loop Z goes up due to it's inductance. The lower the
loop DC resistance the bigger Rs needs to be, & the more Cs may have an effect.
If the loop is made more sensitive with several turns, it may be too inductive
(<1mH for 8ê system) & treble will be reduced!
Why don't U send an interesting bul?
73 De John, G8MNY @ GB7CIP
Read previous mail | Read next mail
| |