I have reverse engineered this QRO Bridge. It was quite straight forward.
SPECIFICATION Ú===================¿
Frequency range 1.8-54MHz ³ ÚÄÄÄÄÄÄÄÄÄ¿ ³
Impedance 50ê ³ ³ \ ³ o ³
Peak Power 2kW ³ ÃÄÄÄÄÄÄÄÄÄ´ _ ³
Connection SO239 ³ ~~~~~~~~~ <_> ³
Accuracy ñ(5% of reading +1% of full scale) ³___________________³
VSWR Insertion 1.05:1 ß ß
THE CIRCUIT
--------- HEAD UNIT -------
XMTR o)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄ(o LOAD
ÃÄÄÄÄ======= C1³/\ ³
³ T1 CCCCCCC === ³
³ ³ ³ ³ /'³ ³
ÃÄ´ÃÄ)ÄÄÁÄÄ)ÄÄÂÄÁÄ´ÃÄ´
³n15 ÃÄ68ÄÄ´ ³ n15 ³
³ _³_ _³_ ÀÄ2k2ÄÄ´ ----------- METER BOX -------
³ D1\_/ \_/D2 ³ wh R \~ ~ ~ ~ ~ ~ \ ___ 200uA
³ ³ ÃÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo \ VAR Úo \ +/SWR\640ê
³ ³ ³ ³ bn <ÄÄoÄÄ68kÄ´ <ÄÄoÂÄ<Meter>¿
³ ÃÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo SWR Ào ³ \___/ ³
³ ³ ³ ³ gn F 2000W À´ÃÄÄÄÄÄÄ´
³ ÃÄ68kÄ)Ä20kPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo 10n ³
³ ³ ³ ³ bl 200W ³
³ ÃÄ10kÄ)Ä20kPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo ³
³ ³ ³ ³ rd 20W ³
³ ÃÄÄÄÄÄ)Ä10kPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo ³
³ 1n=== ===1n ³ bk ³
ÀÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
WHO IT WORKS
A short length of thick wire goes through the screened ferrite transformer T1
making a 1 turn primary, & the lead joins the XTMR & LOAD sockets together. A
pickoff voltage attenuator is formed with trimmer C1 & the 2 150pF caps. This
RF voltage is fed to T1 secondary centre tap. Load current is transformed by T1
into a voltage across the 5W non inductive 68ê.
When the load is exactly 50ê the diode D2 sees no RF as the voltage sample &
the current sample are in opposition & cancel dependent on the calibration of
the trimmer C1.
The 2k2 is needed to complete the DC meter circuit & will affect the
calibration of the lowest frequency, as will the L value of T1.
Diode D1 however sees the voltage tap & the current sample added together &
produces DC across the 1nF, & feeds this to the meter box on the brown wire for
SWR full scale, & via the calibration power presets on green, blue & red wires.
SWR voltage readings will be present on D2 when the load is not exactly 50ê are
fed out on the white wire.
The meter box has a 1 wafer switch that forms a 2 switch bank connected as
show, to give all the functions.