Subj: PTT line for Drake L-4B PA
Path: IZ3LSV<IK2XDE<DB0RES<DK0WUE<7M3TJZ<PY1AYH<CX2SA<GB7LDI<GB7CIP
Sent: 090304/2312Z @:GB7CIP.#32.GBR.EU #:19716 [Caterham] $:19716_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

By G8MNY                                    (Updated Jul 07)
(8 Bit ASCII Graphics use code page 437 or 850)
THE PROBLEM
If wired directly to a IC735 Tx send connector, the IC735 reed relay contacts
weld up with the linear relay's back emf.

            L I N E A R                                 I C  7 3 5
20V AC            S4   _____                             SEND PTT
())))ÄÄ´>ÃÄÄÂÄÄÄÂÄ/oÄÄ´relayÃÄÄÂÄÄ´>ÃÄÄo                 o)ÄÄ> \ Tx reed
=====      ===  ³      ~~~~~   ³      PTT                 ³    ³ relay
        100u³  2k2         10n===     GND                 ³    ³ contact
      ÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄo                  ÀÄÄÄÄÁÄÄÄ

This old large valve HF PA uses an inductive 12V PTT relay that is runs on
unregulated 18V.

MY CURE
Not wishing to modify either pieces of kit, I chose to find a simple fool proof
solution in the inter connecting lead.

To stop the back emf & inrush current to the IC735's reed relay SEND contact,
I added a 35V 4u7 in series with a 100ê across linear's PTT 2 pin plug.

             L I N E A R                              I C  7 3 5
 20V            S4     _____               P L U G      SEND PTT
())))ÄÄ´>ÃÄÄÂÄÄÄÂÄ/oÄÄ´relayÃÄÄÂÄÄ´>ÃÄÄo  ÄÄÄÂÄÄÄÄÄÄÄ(o o)ÄÄ \  Tx reed
=====      ===  ³      ~~~~~   ³      PTT   100ê     ³   ³    ³ relay
            ³   ³              ³             ³+      ³   ³    ³ contact
        100u³  2k2         10n===     GND   === 4u7  ³   ³    ³
      ÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄo  ÄÄÄÁÄÄÄÄÄÄÄÙ   ÀÄÄÄÄÁÄÄÄ
                                            L E A D

The added operate & release delay is not detectable (1mS?), & there is no
longer a spark & shocking back emf, if U manually earth the phono plug etc.

Recently overhalled the PA & modified the PTT relay with the usual diode across
it, to stop all relay back emf. 

             L I N E A R                              I C  7 3 5
 20V            S4      _____               P L U G      SEND PTT
())))ÄÄ´>ÃÄÄÂÄÄÄÂÄ/oÄÂÄ´relayÃÄÂÄÄÂÄÄ´>ÃÄÄo  ÄÄÄÄÄÄÄÄÄÄ(o o)ÄÄ \  Tx reed
=====      ===  ³    ³  ~~~~~  ³  ³      PTT           ³   ³    ³ relay
            ³   ³    ÀÄÄÄ´<ÃÄÄÄÙ  ³                    ³   ³    ³ contact
        100u³  2k2    1N4001  10n===     GND           ³   ³    ³
      ÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄo  ÄÄÄÄÄÄÄÄÄÄÙ   ÀÄÄÄÄÁÄÄÄ


     
Why Don't U send an interesting bul?

73 de John, G8MNY @ GB7CIP